Here you will find presentations given at COMSOL Conferences around the globe. The presentations explore the innovative research and products designed by your peers using COMSOL Multiphysics. Research topics span a wide array of industries and application areas, including the electrical, mechanical, fluid, and chemical disciplines. Use the Quick Search to find presentations pertaining to your application area.
COMSOL-News-Magazine-2017
COMSOL-News-Magazine-2017-Special-edition-acoustics
COMSOL-News-Magazine-2016

A Methodology For The Simulation Of MEMS Spiral Inductances Used As Magnetic Sensors

S. Druart, D. Flandre, and L.A. Francis
Université catholique de Louvain - ICTEAM, Louvain-la-Neuve, Belgium

In this paper, a methodology to simulate the electric behavior of spiral inductances is presented and discussed. All the methodology is built with the COMSOL software used with the Matlab scripting interface and then allows performing fully parameterized simulations. The program architecture is explained and is used to simulate two applications. The first calculates the voltage induced by an ...

Verification and Time Performance Analysis of COMSOL v3.5a for Solving the Electromagnetic Problem in a Superconductor Slab

J. Lloberas[1], J. López[1], E. Bartolomé[2], and X. Granados[3]
[1]Universitat Politècnica de Catalunya, Barcelona, Spain
[2]Escola Universitària Salesiana de Sarrià, Barcelona, Spain
[3]Institut de Ciència de Materials de Barcelona, Barcelona, Spain

Numerical analysis based on finite element method (FEM) represents a powerful approach to solve electromagnetic problems. For instance, FEM methods have been broadly used to calculate the critical state current distribution in high temperature superconductors of various geometries. In the near future, we intend to develop a tool in COMSOL v3.5a for the analysis of power applications, such as ...

COMSOL application in modeling PEMFC transients

X. Li
Chinese Academy of Sciences, Dalian Institute of Chemical Physics, Beijing, China

We studied the transient characteristics of PEMFC and water transport during PEMFC start-up, concerning the following aspects: Effect of air stoichiometry change on transient behavior of PEMFC, Transient behavior of water transport during PEMFC start-up, and high temperature PEMFC modeling.

A High-Efficiency Micro-Channel Regenerative Heat Exchanger for Fluid Processing

O. Yildirim, and Z. Guo
Intellectual Ventures Laboratories
Bellevue, WA

Regenerative heat exchangers (RHX) find widespread applications in liquid food or pharmaceutical processing as well as in reaction engineering. Whereas \"large\" RHX systems have been in use for a long time, their smaller micro-channel counterparts are a more recent area of interest. Here, we describe the design and development of a novel micro-channel counter-current regenerative heat ...

Evaluation of Tensile Modulus of Carbon Nanotube Bundle Based Composite with Interface Using Finite Element Method

M. S. Islam, F. O. Riktan, S. C. Chowdhury, M. M. R. Chowdhury, and S. Ahmed
Bangladesh University of Engineering & Technology (BUET)
Dhaka, Bangladesh

Carbon Nanotubes (CNTs) have remarkable mechanical, thermal and electrical properties. The properties of CNTs depend on atomic arrangement (how the sheets of graphite are rolled), the diameter and length of the tubes and morphology of nanostructure. In this paper effective elastic properties of CNT based polymer composites are evaluated using a square Representative Volume Element (RVE) in ...

Effect of Gas Flow Rate and Gas Composition in Ar/CH4 Inductively Coupled Plasmas

L. Tong
Keisoku Engineering System Co. Ltd.
Japan

The discharge properties in low pressure inductively coupled Ar/CH4 plasmas operating at an RF frequency of 13.56 MHz and total gas pressure of 20 mTorr are studied in this work. The calculation of gas flow is performed in coupling with the plasma simulation. The gas flow rate is varied from 20 to 1000 sccm. The species taken into account include electrons, six kinds of molecules, eleven ...

Electrophoresis and Electroosmosis in the Intracellular Transport of Macromolecules

V. Andreev
University of Miami
Miami, FL

Electric fields are present in biological systems at multiple spatial and temporal scales. Electroosmotic flow results from the action of electric field on the electrical double layer, formed at the fluid/solid or fluid/membrane interface and characterized by its zeta-potential. For the physiological value of zeta-potential (50 mV) and a single charged protein of average size, electroosmotic ...

Electric Field Density Distribution for Cochlear Implant Electrodes

N.S. Lawand[1], J. van Driel[2], P.J. French[2]
[1]Electronic Instrumentation Laboratory (EILab), Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), Delft University of Technology, Delft, The Netherlands
[2]Delft University of Technology, Delft, The Netherlands

Cochlear Implants are implantable devices which bypasses the non-functional inner ear and directly stimulates the hearing nerve with electric currents thus enabling deaf people to experience sound again. Implant electrode array design is limited in electrode count, due to their large size in accordance to scala tympani (ST) with restrictions for deeper insertion in ST thus depriving access to ...

Transient Analysis of an EMVD Using COMSOL Multiphysics

G.E. Stebner[1], C. Hartwig[1]
[1]Ostfalia University, IMEC, Wolfenbüttel, Germany

In this paper an EMVD (Electro-Mechanical Valve Drive) for combustion engines is redesigned to achieve a fail-safe behavior when power loss occurs. The AC/DC Module and the Moving Mesh interface of COMSOL Multiphysics 4.2 are used to build up a transient model. This model also includes the calculation of eddy currents.

Magnetic and Circuital Modeling of a Low Harmonic Pollution Three Phase Transformer

E. Scotoni[1], C. Tozzo[2], D. Zoccarato[1], F. Paganini[1]
[1]TMC Italia, Busto Arsizio, Italy
[2]COMSOL, Brescia, Italy

A three phase transformer with very low harmonic pollution transferred back to power line is here presented. In fact, thanks to the described setup, intermediate harmonics (5th and 7th) are not going out back to the power line feeding the primary. These results has been extensively validated versus measurements performed on produced and shipped machine. With these results, TMC is then featuring ...