Permanent magnet demagnetization at high temperature
Application ID: 153291
Permanent magnet manufacturers will place the magnets in a high-temperature oven to apply cyclic temperature loading during the magnet design process, to observe the demagnetization state of the magnets. The heating process is usually so slow that the temperature distribution inside the magnet can be considered uniform. As a demonstration case, this case simulates the demagnetization state caused by the temperature rise in this process, and can serve as a quickly reference case for relevant users to learn. If the influence of temperature non-uniformity is considered in subsequent work, solid heat transfer can be easily added to this case. The modeling idea in the model and the BH curve data are available from the case : https://cww.comsol.com/models/modelinfo/?id=139621
この model の例は, 通常次の製品を使用して構築されるこのタイプのアプリケーションを示しています.
ただし, これを完全に定義およびモデル化するには, 追加の製品が必要になる場合があります. さらに, この例は, 次の製品の組み合わせのコンポーネントを使用して定義およびモデル化することもできます.
アプリケーションのモデリングに必要な COMSOL® 製品の組み合わせは, 境界条件, 材料特性, フィジックスインターフェース, パーツライブラリなど, いくつかの要因によって異なります. 特定の機能が複数の製品に共通している場合もあります. お客様のモデリングニーズに適した製品の組み合わせを決定するために, 製品仕様一覧 を確認し, 無償のトライアルライセンスをご利用ください. COMSOL セールスおよびサポートチームでは, この件に関するご質問にお答えしています.