SIMULATION SUCCESS STORIES

Researchers in Germany Simulate Corrosion Protection for Submarines

航空宇宙 & 防衛

David Schaefer
University of Duisburg-Essen, Duisburg, Germany

Germany's Technical Center for Ships and Naval Weapons, Bundeswehr, Germany

Submarines create underwater electric potential (UEP) signatures when using corrosion protection systems. These signatures are detectable by enemy vessels, an undesirable effect of the corrosion protection. Germany’s Technical Center for Ships and Naval Weapons (WTD 71) has worked with the Laboratory for General and Theoretical Electrical Engineering (ATE) at the University of Duisburg-Essen to research these UEP signatures in order to reduce them.

Using COMSOL, the team simulated the electric potential distribution on the hull of a submarine, indicating whether or not the material is protected from corrosion. The higher the electric potential, the more the hull is protected. After this, they modeled the signature left by the different electric potentials. The general notion was that a higher amount of corrosion leads to a more detectable signal, which is mostly true. Furthermore, the results showed that the signature is actually the least detectable between zero corrosion protection and the standard operating conditions for full corrosion protection.

  •  /
1
Loading PDF...

Suggested Stories

Man-Made Stars: Evaluating Structural Integrity in High-Performance Nuclear ...

Man-Made Stars: Evaluating Structural Integrity in High-Performance Nuclear Fusion Machines for Power Generation

For over 50 years, power generation through nuclear fusion has been the focus of international research efforts to ...

Promoting Industrial Innovation with Custom Simulation Apps

Promoting Industrial Innovation with Custom Simulation Apps

Simulation apps enable organizations without a simulation expert to leverage the power of numerical simulation. Edward ...

Upgrading the Nuts and Bolts of the Electrical Grid for a New Generation

Upgrading the Nuts and Bolts of the Electrical Grid for a New Generation

Migrating the electrical grid to a “smart grid” is usually discussed in terms of IT issues or embedded systems. Yet, ...

高性能タングステン材料のCVDプロセスの最適化

高性能タングステン材料のCVDプロセスの最適化

ドイツの Forschungszentrum Jülich GmbH(FZJ), エネルギー気候研究所, および Max Planckプラズマ物理研究 ...