High-Cycle Fatigue Analysis of a Cylindrical Test Specimen

Application ID: 14047


A benchmark model for the fatigue module. A cylindrical test is subjected to non-proportional loading. Three stress based models: Findley, Matake, Normal stress, are compared to analytical values and to each other. The non-smooth behavior of the Matake model is captured and discussed.

This application was built using the following:

疲労解析モジュール

The combination of COMSOL® products required to model your application depends on the physics interfaces that define it. Particular physics interfaces may be common to several products (see the Specification Chart for more details). To determine the right combination of products for your project, you should evaluate all of your needs in light of each product\'s capabilities, consultation with the COMSOL Sales and Support teams, and the use of an evaluation license.