COMSOL Not Starting on Some of the More Recent Intel Processor Models

ソリューション番号: 1305 対応: COMSOL Multiphysics バージョン: 6.1

COMSOL Multiphysics won't start on my computer, which uses a new Intel Xeon processor. I can see the splash screen, but the program doesn't go beyond that. So far, this issue has been observed on Intel® Xeon® w3-2435, ...


What are batch licenses and how can I use them?

ソリューション番号: 1304 バージョン: すべてのバージョン

##What are Batch Licenses? The license file for COMSOL Multiphysics® contains a list of license features that correspond to the different COMSOL products and software components. With a single Floating Network ...


COMSOL Troubleshooting Guide

ソリューション番号: 1303 バージョン: すべてのバージョン

## General Issues * KB 933: Troubleshooting graphics issues * KB 1083: Error: An error has occurred. See the log file C:\Users... * KB 1285: Graphics Window not responding on computer with Intel Iris Xe graphics chip * ...


The Magnetic and Electric Fields Interface with Electrical Circuit Gives an Unexpected Error for Transient Studies

ソリューション番号: 1301 バージョン: 6.1

After installing Update 1 for COMSOL Multiphysics 6.1, I receive an unexpected error when solving a transient study with the Magnetic and Electric Fields and Electrical Circuit interfaces. The log file that I access ...


COMSOL 6.1 macOS Apple Silicon Native Support

ソリューション番号: 1300 バージョン: 6.1

Please note This entry concerns COMSOL 6.1. For COMSOL 6.0, please see Knowledge Base 1294 System Requirements COMSOL 6.1 for macOS Intel can not be used under Rosetta on Apple Silicon computers. LiveLink for MATLAB ...


COMSOL Software Architecture

ソリューション番号: 1299 バージョン: すべてのバージョン

#Overall Architecture The following diagram shows the overall architecture of a network, including computers running COMSOL Multiphysics, COMSOL Multiphysics Server, COMSOL Client, compiled COMSOL apps; external ...


COMSOL Not Working on a Linux Cluster

ソリューション番号: 1298 対応: COMSOL Multiphysics, COMSOL Server バージョン: 6.1, 6.0, 5.6

I am observing that distributed cluster jobs on Linux are not starting up. I am receiving error messages from MPI. The underlying reason for COMSOL not working on a Linux cluster might be that the network interface ...


Failed to Connect to Apache Solr

ソリューション番号: 1297 対応: COMSOL Model Manager バージョン: すべてのバージョン

When trying to connect to my local Model Manager I receive an error message that says Failed to connect to Apache Solr The most likely cause for this error message is that the index used by the Model Manager search ...


Warning When Trying to Add a Local Database Stored on a Cloud Drive

ソリューション番号: 1295 対応: COMSOL Model Manager バージョン: 6.1, 6.0

A warning message is shown informing me of potential data loss when I try to add a local Model Manager database stored on a cloud drive. Cloud storage software typically allows files to be placed in a local file system ...


How can I Migrate my Local Model Manager to the Database of a Model Manager Server

ソリューション番号: 1296 対応: COMSOL Model Manager, COMSOL Model Manager Server バージョン: すべてのバージョン

A local Model Manager database and the database of a Model Manager server installation use different underlying software components. It is therefore not possible to directly move a local database into a Model Manager ...